Lesson 7: Annotating

This walk-through demonstrates how you can annotate your design in OrCAD Capture 22.1 (2022). After you complete the topic, you will be able to:

  • Edit reference designator text
  • Automatically update schematic annotation
  • Understand the differences between unconditional reference and incremental reference updates

To follow along, continue with the design from the last topic or use the provided design files. If the design files were not downloaded in the beginning of the Capture Walk-Through, the design files for this lesson can be found under the Materials tab.

Open in New Window

Running an Unconditional Update

Note: The design was automatically annotated when parts were placed. The order in which parts are numbered was determined by the order in which they were placed. For educational purposes, this walk-through will discuss additional options for annotating a design.

Step 1: Select Tools > Annotate from the menu.

Step 2: Under Action, select Unconditional Reference Update.

Note: There are multiple options to annotate a selection or your entire design:

  • Select Incremental reference update to annotate only components with question marks in the name.
  • Select the Unconditional reference update to re-annotates all components. Use this option if specific names are not required for components.
  • Select Reset part references to “?” to reset all reference designators to question marks.
Capture22.1 L7 Step3
Configuring an Unconditional Reference Update

Step 3: Under Mode, select Update Instances.

Note: Update Occurrences is recommended for hierarchical designs. Updating instances will update all parts in the design, even parts on unused pages. In other words, unused parts will factor into the annotations.

Step 4: Click OK to run the annotation.

Step 5: You may be prompted that running annotation will clear the undo/redo cache. Click Yes to proceed.

Step 6: You will be prompted that the tool will annotate then save the design. Click OK to proceed.

Capture22.1 L7 Step7
Viewing the Annotation

Step 7: View the schematic. All part references have been updated from left to right.

Resetting Part References

Step 8: Select Tools > Annotate from the menu.

Capture22.1 L7 Step9
Resetting Part References in OrCAD

Step 9: Under Action, select Reset Part References to “?”.

Note: This will reset all reference designators to question marks.

Step 10: Click OK to run the annotation. Click Yes and OK when prompted.

Capture22.1 L7 Step11
Viewing the Annotation

Step 11: View the schematic. The part references have been changed to question marks.

Manually Defining Reference Designators

Capture22.1 L7 Step12
Editing a Reference Designator

Step 12: Double-click reference designator D1 associated with the LED.

Step 13: Enter MAIN_PWR for the value and click OK.

Capture22.1 L7 Step13Note

Note: The reference designator is now underlined, indicating that it has been changed by the user.

Running an Incremental Update

Step 14: Select Tools > Annotate from the menu.

Capture22.1 L7 Step15
Configuring an Incremental Reference Update

Step 15: Under Action, select Incremental Reference Update.

Step 16: Click OK to run the annotation. Click Yes and OK when prompted.

Capture22.1 L7 Step17
Viewing the Annotation

Step 17: View the schematic. The MAIN_PWR annotation remains the same, but all other components have been re-annotated.